Zestawienie parametrów najczęsciej spotykanych kabli koncentrycznych na pasma wlan 2,4 i 5 Ghz wybranych z oferty polskich sklepów internetowych zajmujacych się dystrybucja akcesoriów wlan.
|
|
CNT600 |
CNT400 |
H1000 |
RF10 |
RF240 |
RF5 |
H155 |
CNT200 |
RF100LL |
RG316 |
||
|
Ohm |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
pF/m |
76.8 |
78.4 |
80 |
81 |
75.5 |
82 |
82 |
80.4 |
77 |
82 |
||
|
|
0.87 |
0.85 |
0.83 |
? |
0.86 |
? |
0.81 |
0.83 |
0.85 |
0.70 |
||
|
Ohm/km |
1.7/4 |
4.6/5.4 |
3.2/7.9 |
3/6 |
10.5/11.5 |
12/16 |
15/32 |
17.6/16 |
11/14 |
- |
||
|
dB/100m |
1.4 |
2.9 |
2.7 |
2.3 |
5.3 |
6.4 |
6.5 |
7.4 |
15 |
18.4 |
||
|
dB/100m |
2.6 |
4.1 |
3.9 |
3.1 |
7.5 |
9.1 |
9.3 |
10.5 |
21.3 |
27.2 |
||
|
dB/100m |
3.7 |
5.7 |
5.7 |
4.6 |
10.6 |
12.9 |
13.1 |
15 |
30.1 |
- |
||
|
dB/100m |
5.8 |
9.3 |
9.6 |
8.0 |
17 |
20.4 |
16.6 |
23.8 |
48.6 |
- |
||
|
dB/100m |
7.6 |
12 |
12.3 |
10.7 |
21.6 |
27.3 |
21.6 |
30.1 |
62.6 |
- |
||
|
dB/100m |
8.6 |
13.4 |
13.9 |
12.3 |
24.5 |
30.5 |
30.9 |
34 |
70 |
95.1 |
||
|
dB/100m |
11.8 |
18.1 |
19.7 |
17.5 |
32.7 |
41.6 |
42.3 |
45.4 |
95.4 |
- |
||
|
dB/100m |
12.7 |
19.4 |
21.2 |
19.2 |
35 |
44.5 |
45.2 |
48.8 |
102.3 |
- |
||
|
dB/100m |
14.1 |
21.5 |
23.2 |
21.2 |
38.7 |
48.8 |
49.6 |
53.4 |
114 |
- |
||
|
dB/100m |
20.8 |
32.6 |
- |
- |
60.6 |
- |
- |
80.6 |
183.3 |
- |
||
|
dB/100m |
21.4 |
33.6 |
- |
- |
64 |
- |
- |
83 |
188.5 |
- |
||
|
dB/100m |
22 |
34.7 |
- |
- |
65 |
- |
- |
85.4 |
195.4 |
- |
||
|
dB |
- |
- |
>23 |
- |
- |
>20 |
>23 |
- |
- |
|
||
|
dB |
- |
- |
>20 |
- |
- |
>18 |
>20 |
- |
- |
|
||
|
dB |
- |
- |
>18 |
- |
- |
>17 |
>18 |
- |
- |
|
||
|
dB |
>90 |
>90 |
>83 |
>80 |
? |
>80 |
>81 |
>90 |
? |
|
||
|
dB |
>90 |
>90 |
>83 |
>80 |
? |
>80 |
>81 |
>90 |
? |
|
||
Wymiary
i konstrukcja |
|||||||||||||
|
|
drut BCCAl |
drut BCCAl |
drut Cu |
drut Cu |
drut BACu |
linka Cu |
linka Cu |
drut BC? |
drut BACu |
linka? |
||
|
mm |
4.47 |
2.74 |
2.62 |
2.70 |
1.45 |
19x0.28 |
19x0.28 |
1.12 |
0.51 |
7x0,02 |
||
|
|
FOAM |
FOAM |
FOAM |
FOAM |
FOAM |
FOAM |
FOAM |
FOAM |
FOAM |
TFE |
||
|
mm |
11.56 |
7.24 |
7.15 |
7.25 |
3.81 |
3.9 |
3.9 |
2.95 |
1.52 |
1.52 |
||
|
|
Al |
Al |
Cu |
Al |
DuobondII |
Al |
Al |
Al |
Duofoil |
|
||
|
|
CuSn |
Cu |
Cu |
CuSn |
Cu |
CuSn |
CuSn |
CuSn |
CuTc |
|
||
|
gęstość
pokrycia w % |
? |
? |
50 |
95 |
95 |
90 |
90 |
? |
90 |
95 |
||
|
|
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
||
|
gęstość
pokrycia w % |
- |
- |
- |
- |
- |
- |
- |
- |
- |
|
||
|
mm |
12.45 |
8.13 |
7.8 |
7.95 |
? |
4.5 |
4.5 |
3.66 |
? |
|
||
|
|
PE |
PE |
PCV |
PCV/PE |
PE |
PCV |
PVC |
PE |
PCV |
FEP |
||
|
mm |
14.99 |
10.29 |
10.3 |
10.3 |
6.1 |
5.4 |
5.4 |
4.95 |
2.79 |
2.49 |
||
Własności
mechaniczne |
|||||||||||||
|
mm |
38 |
25.4 |
75 |
100 |
30 |
70 |
35 |
12.7 |
? |
|
||
|
N |
? |
720 |
450 |
? |
? |
? |
100 |
180 |
? |
|
||
|
g/m |
200 |
100 |
120 |
157 |
51 |
48 |
38 |
30 |
? |
|
||
|
-5 |
|
|
|
|
|
|
|
|
|
|
||
|
-40 do
+80 |
|
|
|
|
|
|
|
|
|
|
||
|
-30 do
+75 |
|
|
|
|
|
|
|
|
|
|